Home ProductsMicro Bulk Tanks

Oxygen Micro Bulk Tanks 7.5m3 Cryogenic 5m3 Medical CO2

Certification
China Tianjin Mikim Technique Co., Ltd. certification
I'm Online Chat Now

Oxygen Micro Bulk Tanks 7.5m3 Cryogenic 5m3 Medical CO2

Oxygen Micro Bulk Tanks 7.5m3 Cryogenic 5m3 Medical CO2
Oxygen Micro Bulk Tanks 7.5m3 Cryogenic 5m3 Medical CO2 Oxygen Micro Bulk Tanks 7.5m3 Cryogenic 5m3 Medical CO2

Large Image :  Oxygen Micro Bulk Tanks 7.5m3 Cryogenic 5m3 Medical CO2

Product Details:
Place of Origin: henan
Brand Name: MKIMM
Certification: ISO
Model Number: MKIMM
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: bargain
Packaging Details: wooden box
Delivery Time: 15days
Payment Terms: T/T,L/C,Paypal,Alipay,West Union and so on
Supply Ability: 25 every month

Oxygen Micro Bulk Tanks 7.5m3 Cryogenic 5m3 Medical CO2

Description
Max Working Pressure(MPa): 2.3 MPa Applicable Industries: Manufacturing Plant, Food & Beverage Factory,
Video Outgoing-inspection: Provided Marketing Type: Ordinary Product
Warranty Of Core Components: 1 Year Local Service Location: None
After-sales Service Provided: Online Support Certification: CE ISO ASME
High Light:

Oxygen Micro Bulk Tanks

,

7.5m3 Micro Bulk Tanks

,

5m3 microbulk co2

5m3 Small Medical Oxygen Micro Bulk Cryogenic Storage Tank

 

Description

5m3 Small Medical Oxygen Micro Bulk Cryogenic Storage Tanks can directly supply high-purity liquid gas installed in small cryogenic storage tanks through small tankers, enjoying continuous and uninterrupted gas supply, eliminating the trouble of handling steel cylinders, making low-temperature liquid gas supply Fast and easy, safe and economical. Especially in improving production efficiency and reducing waste, the results are remarkable.

 

Specification

volume(m3) working pressure(MPa) working medium dimension(mm) net weigh(kg)
1m3 1.6 LO2,LN2,LAr,LNG 1300*1300*2326 720
2.5 LO2,LN2,LAr,CO2 1300*1300*2326 720
3.4 LO2,LN2,LAr 1300*1300*2326 1096
2m3 1.6 LO2,LN2,LAr,LNG 1750*1750*2741 1440
2.5 LO2,LN2,LAr,CO2 1750*1750*2741 1560
3.4 LO2,LN2,LAr 1600*1600*2390 1780
3m3 1.6 LO2,LN2,LAr,LNG 1850*1850*2869 1814
2.5 LO2,LN2,LAr,CO2 1850*1850*2869 1990
3.4 LO2,LN2,LAr 1850*1850*2869 2408
5m3 0.8 LNG 2300*2300*3160 2426
1.6 LO2,LN2,LAr,LNG 2150*2150*3095 2757
2.5 LO2,LN2,LAr,CO2 2150*2150*3095 3102
3.4 LO2,LN2,LAr 2150*2150*3095 3483
7.5m3 1.6 LO2,LN2,LAr,LNG 2350*2350*3210 4326

 

micro bulk tank

Advantage:

Through the development of 5m3 Small Medical Oxygen Micro Bulk Cryogenic Storage Tanks, the shortcomings of steel cylinders and dewars that need to be loaded, unloaded, handled, stored and moved have been greatly improved, and the production efficiency has been greatly improved, and the contact opportunities with high-pressure steel cylinders and cryogenic dewars have also been eliminated. Improve the safety of production. The highlight of the project is that it not only conforms to the development direction of economy and low-carbon economy, but also can achieve energy-saving effect.

micro bulk tank

Precautions

When designing a low-temperature tank, due to the conduction of the low-temperature medium in the tank, the foundation soil is prone to freeze swell and cause the soil to bulge, thereby causing foundation damage. Therefore, in order to eliminate this disadvantage, in addition to the tank bottom and the foundation bottom In addition to the insulation measures between the surfaces, anti-freezing measures must also be taken for the tank foundation. There are two common methods. One is to use an electric or other heating system in the foundation bottom plate, that is, to make a raft-type foundation with a circulating heating system. The other is to use the base plate to be overhead, and the air layer formed by the overhead is used to separate the base plate from the foundation soil. The former is generally not used due to the high cost of the heating system. In most of the low temperature tanks introduced and constructed, the overhead raft foundation form is commonly used. The net height of the overhead layer is generally determined according to the process piping and equipment layout requirements, but also needs to be determined after a certain temperature conduction calculation according to the temperature of the storage medium in the tank. Overhead raft foundation can be divided into single raft (cap) and double raft (cap) overhead. In the case of good geological conditions, the double raft foundation can generally be used; but due to low temperature storage. The requirements for the foundation settlement of the tank are relatively high. In most cases, especially on soft soil foundations with poor geological conditions, single raft (cap) pile foundations are mostly used, and sometimes double rafts (caps) are used. ) pile foundation.

Contact Details
Tianjin Mikim Technique Co., Ltd.

Contact Person: admin

Tel: +8619337261669

Send your inquiry directly to us (0 / 3000)