Product Details:
|
Core Components:: | Pressure Vessel, Pump | Structure: | Tube Heat Exchanger |
---|---|---|---|
Maximum Working Pressure:: | 3.0MPa | Key Selling Points:: | Automatic |
Application:: | Pipe Fitting | After Warranty Service:: | Video Technical Support, Spare Parts, Field Maintenance And Repair Service |
Video Outgoing-inspection:: | Provided | Marketing Type:: | Ordinary Product |
Warranty Of Core Components:: | 3 Years | Liquid Flow Rate:: | Max 50 M3/h |
High Light: | Q245R Shell Type Condenser,SS347 Shell Type Condenser,800 degree Titanium Tube Heat Exchanger |
Titanium Fabricated Shell And Tube Heat Exchanger
Description
Shell and tube heat exchanger is a kind of working medium from the head of the inlet pipe into the heat transfer tube, the process can achieve one tube, two tube and four tube structure according to the process requirements; The other working medium enters into the shell by the inlet pipe at one end of the shell and distributes evenly outside the heat transfer tube. As a heat transfer element - heat exchange tube, according to the process requirements of brass tube, copper fin tube and steel tube, so as to ensure that different physical properties, different temperatures of the working medium in the heat exchanger to achieve the heat exchange, to achieve the purpose of cooling or heating.
Parameter
Heat Exchange Area (m2) | As per request |
Working pressure (MPa) |
Negative pressure -0.1~35 as per request |
Working temperature (°C) |
-269~800 as per request |
Shell Diameter (mm) |
450~4000 as per request |
Tube Diameter (mm) |
OD6, OD9, OD12, OD16, OD19, OD25, OD32 or as per request |
Material |
Stainless Steel SS304, SS316L. SS321, SS310, SS347 Carbon Steel Q245R, Q345R 15CrMoR, Titanium, Copper, Hastelloy, Nickle Alloy (Inconel, Monel) or as per reuquest |
Weld Type | Expansion welding, Regular welding, or both |
Features:
The shell-and-tube heat exchanger has a simple, compact structure and low fluid resistance, and can be used to manufacture large-scale equipment, but its pressure and temperature resistance is lower than that of the block-hole type. Condenser is better, and it can also be used as general heating equipment after being processed by special technology. Usually a series of baffles perpendicular to the tube bundle are installed outside the tube. At the same time, the connection between the tube and the tube sheet and the outer shell is rigid, and there are two different temperature fluids inside and outside the tube.
Cooler cleaning:
1. After the cooler works for a long time, the surface of the tube wall is gradually formed with dirt, which affects the heat exchange effect. At this time, it should be cleaned, and the cleaning cycle can be determined in about one year according to the cleanliness of oil and water.
2. When cleaning, kerosene (gasoline, trichloroethylene) can be used to wash the tube bundle, end cover and shell, etc. until they have a metallic luster. After reassembly, perform a pressure test of 1.25 times the design pressure without leakage.
Contact Person: admin
Tel: +8619337261669