Product Details:
|
Video Outgoing-: | Provided | Core Components:: | Pump |
---|---|---|---|
Structure: | Tube Heat Exchanger | Maximum Working: | 4Mpa |
Dimension(L*W*H):: | 330mm*180mm*540mm | Warranty:: | 1 Year |
Weight:: | 8 KG | ||
High Light: | 4Mpa Shell Tube Heat Exchanger,4 Mpa Shell And Tube Heat Exchanger,Easy Installing Shell Tube Heat Exchanger |
Easy installing shell and tube heat exchange for sale
Easy installing shell and tube heat exchange for sale ,The heat transfer area is wide: the heat transfer tube of the cooler is designed with bare tubes, and the contact area is wide, the heat transfer is indeed good, and the cooling effect is good. Good heat transfer tube: the use of good heat conductivity of99.9% pure copper, for the most suitable cooling tube.No oil leakage: because the board and the body of the integrated design, can avoid water and oil mixing problems, and at the same time before leaving the factory through airtight test is really tight, so it can achieve the purpose of leak proof.Easy assembly: the foot seat can be 360 degrees of freedom rotation and angle of ontology for free to change the direction of the assembly, the foot seat can be welded directly in any position or machine oil tank, convenient and simple.Anti pollution: suitable for the cooling of dirty and high viscosity oil, and also for water to water and water to heat exchange of gas.
Specifications
Item |
Heating capacity (kw) | water flow (m³/h) |
PVC shell dimention (A*B) (mm) |
Titanium twisted tubing (mm) |
refrigeration import &export (mm) |
water import &export (mm) |
NTTP038-B1 | 3.8 | 1.8 | φ160*330 | φ12.7*0.6 | φ12.7/φ12.7 | 50 |
NTTP045-B1 | 4.5 | 2 | φ160*330 | φ12.7/φ12.7 | 50 | |
NTTP053-B1 | 5.3 | 2.5 | φ160*330 | φ12.7/φ12.7 | 50 | |
NTTP078-B1 | 7.8 | 3.5 | φ160*330 | φ12.7/φ12.7 | 50 | |
NTTP080-B1 | 8 | 3.8 | φ200*500 | φ12.7/φ12.7 | 50 | |
NTTP095-B1 | 9.5 | 4.2 | φ200*500 | φ12.7/φ12.7 | 50 | |
NTTP113-C2 | 11.3 | 5 | φ200*500 | φ16*0.6 | φ12.7/φ12.7 | 50 |
NTTP120-C2 | 12 | 5.3 | φ200*500 | φ12.7/φ12.7 | 50 | |
NTTP125-C2 | 12.5 | 5.5 | φ200*500 | φ12.7/φ12.7 | 50 | |
NTTP140-C2 | 14 | 6.2 | φ200*500 | φ12.7/φ12.7 | 50 | |
NTTP170-C2 | 17 | 7.5 | φ200*500 | φ12.7/φ12.7 | 50 | |
NTTP210-D2 | 21 | 9.2 | φ200*500 | φ19*0.6 | φ12.7/φ12.7 | 50 |
NTTP260-D2 | 26 | 12 | φ200*500 | φ12.7/φ12.7 | 50 | |
RE: 1. The data in the list is our suggestion, and we can produce the heat exchanger according to customers’ requirement. 2. Heating capacity is measured under DB/WB at 20°C/ 15°C, and inlet water temp. is 26°C, outlet water temp. is 28°C. And the highest outlet water temp. is 45°C. |
FAQ
Contact Person: admin
Tel: +8619337261669