Product Details:
|
Showroom Location: | None | Working Medium: | LO2/LAr/LN2/LCO2/LNG/Liquified Ethylene And Etc |
---|---|---|---|
Adiabatic Mode: | Vacuum Insulation | Certification: | ASME, GB150, ISO9001 |
Weight: | Actual Weight | Working Pressure: | 1.6Mpa |
Structure: | Horizontal Or Vertical Type Vessels | Local Service Location: | None |
Color: | White Or Customized | ||
High Light: | 1.6Mpa double wall cryogenic storage tank,LO2 double wall cryogenic storage tank,Liquified ethylene cryogenic storage vessels |
LNG Tank For Storage Liquified Natural Gas
Description
Since LNG storage tanks are not only important equipment for connecting upstream production and downstream users, but also account for a high proportion of the total investment in LNG peak-shaving liquefaction plants and terminals, the current market attaches great importance to LNG storage tanks. Design and build.
Parameter
NO. | Medium | Inner tank size(Dia*L*Thickness mm) | Outer tank size(Dia*L*Thickness mm) | Outer size(Dia*H/L(mm) | Net weight(Kg) |
1 | LNG | DN2200*4450*6/6 | DN2700*5070*8 | Φ2716*7091 | 8770 |
2 | LNG | DN2400*5760*6/6 | DN2900*6440*10 | Φ2920*8539 | 12400 |
3 | LNG | DN2700*7760*8/8 | DN3200*8410*10 | Φ3220*10627 | 18885 |
4 | LNG | DN2700*9500*8/8 | DN3200*10300*10 | Φ3220*12810 | 23345 |
5 | LNG | DN2900*14100*8/8 | DN3400*15020*12 | Φ3424*17629 | 37880 |
6 | LNG | DN1400*2740*6/6 | DN1900*3360*8 | Φ1916*4712 | 4020 |
7 | LNG | DN1800*3300*6/6 | DN2300*4000*8 | Φ2316*5538 | 6120 |
8 | LNG | DN1800*3300*6/6 | DN2300*3910*8 | Φ2316*5808 | 5465 |
9 | LNG | DN1800*5250*6/6 | DN2300*5860*8 | Φ2316*7725 | 7530 |
10 | LNG | DN1900*6400*6/8 | DN2400*7020*8 | Φ2416*8456 | 9480 |
11 | LNG | DN1900*6400*6/8 | DN2400*7020*8 | Φ2416*8922 | 9375 |
12 | LNG | DN2400*5760*8/8 | DN2900*6440*10 | Φ2920*8574 | 13060 |
13 | LNG | DN2600*8480*8/10 | DN3100*9200*10 | Φ3120*11378 | 19505 |
14 | LNG | DN2500*11310*8/8 | DN3000*12110*10 | Φ3020*14551 | 24090 |
15 | LNG | DN2900*14100*10/10 | DN3400*15020*12 | Φ3424*17666 | 39135 |
16 | LNG | DN2500*11310*12/14 | DN3000*12210*10 | Φ3020*14551 | 28300 |
17 | LNG | DN2800*15230*14/16 | DN3300*16150*12 | Φ3324*18739 | 45620 |
Precautions
1. The installation site of the lng cryogenic storage tank should have good ventilation, generally it should be installed outdoors, surrounded by fences, and there should be no open flames, combustibles and explosives and low-lying places within 5m;
2. The lng cryogenic storage tank has a grounding device to remove static electricity and a lightning protection device. The grounding resistance is not more than 10Ω; the maximum impact resistance of the lightning protection device is 30Ω, and it should be tested at least once a year;
3. When the valves, instruments, pipes, etc. on the lng cryogenic storage tank are frozen, use nitrogen, air or hot water at 70 to 80 °C to freeze, and it is strictly forbidden to heat with an open flame;
4. When the lng cryogenic storage tank has been emptied of liquid and cannot be heated immediately, close all valves immediately. Because the temperature in the tank is very low, the moist air will penetrate into the interior through the connected pipes, causing the accident of freezing and blocking the pipes.
use
First, it is used for peak load and accident peak shaving of urban pipeline network gas supply; second, it is used as the main gas source for pipeline gas supply in large and medium cities; third, it is used as the gas source for gasification of LNG communities; Gas fuel; fifth is used as aircraft fuel; sixth is distributed energy system.