Product Details:
|
Product Name: | Cryogenic Storage Tank | Outer Material: | Q345R |
---|---|---|---|
Volume: | 5000L | Working Pressure: | 1.6Mpa |
Working Temperature: | -196/+20 ℃ | Video Outgoing-inspection: | Provided |
High Light: | 5000L Liquid Cryogenic Storage Tank,20m3 Liquid Cryogenic Storage Tank |
Description
Vacuum powder insulation liquid cryogenic storage tank is used for storage and supply of cryogenic liquid like liquid oxygen, liquid nitrogen,liquid argon and liquid carbon dioxide.It has advantages of area-saving, safe, reliable and convenient maintenance, etc, and has m been widely used in gas, chemical,mechanical, metallurgy, electronics, medical, glass, mining, nuclear power and other industries. The tank supplies cryogenic liquid from the bottom. It can be connected with the exterior vaporizer and cryogenic pump. It can also be designed and manufactured according to users' requirements.
Parameter
Model
|
CFL5/1.6
|
Effective Capacity
|
5000L
|
Working Pressure
|
1.6Mpa
|
Design Temp
|
-196°C (inner tank)
|
Inner Material
|
S30408
|
Outer Material
|
Q245R
|
Insulation Type
|
High Vacuum powder insulation
|
Fillling Rate
|
95%
|
Loading medium
|
LO2,LN2,LAr
|
Design Standard
|
a.GB150
b.GB/T 18442< Cryogenic >Insulation Pressure Vessels>
c.TSGR0004
|
Q. How does a differential pressure (dp) gauge measure level in a cryogenic tank? A. A differential pressure (dp) gauge has two ports, a high pressure port and a low pressure port. On a cryogenic tank the high pressure port of the gauge is piped to the bottom of the tank. Since the tank is pressurized the low pressure port of the gauge is piped to the top of the tank, the vapor space. The difference between the high and the low pressures then represent the height of the liquid only. On Nuzhuo level gauges, differential pressure is relayed to the gauge through a magnetically coupled sensor-indicator design.
Contact Person: admin
Tel: +8619337261669